| Emulsion DAQ system | |
Scan back location | ![]() |
S-UTS | Demonstration? |
European System | ![]() |
| Emulsion Analysis Software | ![]() |
| BAM | ![]() |
| Emulsion Processing ( Development etc. ) | ![]() |
| Refresh | Demonstration? |
| CS | ![]() |
| OPERETTA | Informal discussion |
| Test Experiments | |
Nu_e scan back location | ![]() |
Brick to brick connection | ![]() |
Momentum by MCS | ![]() |
Electron ID | ![]() |
MeV electron | ![]() |
Electron energy ( 10 - 100 GeV/c ) | ![]() |
Hadron secondary interaction | ![]() |
Gamma detection ( pi_0 detection ) | ![]() |
Large angle muon scattering | ![]() |
p/pi/mu ID | ![]() |
We propose to restrict ourself this time to concentrate on discussions on items below and to define responsible groups on them. (1) Test for Scan Back Location for QE nu_e and tau->e ( Koichi Kodama ) Scheme (a) Expose bricks to very low intensity electron beam ( 1 electron / spill ) (b) Replace CS each spill ? to distinguish each electron beam (c) Try scan back method to reach incident electron beams Do we have a suitable low intensity beam line ? How to continue scan back when followed up track disappers due to e-pair conversion ? Efficiency evaluation (2) Test for Scan Back Location for NC like events ( Shigeki Aoki ) Scheme (1) Expose mini wall ( 1+9 bricks ) to a few GeV/c pi- (2) First try to locate pi- interaction in the first wall ( only 1 brick ) (3) Then try to connect secondaries to down side wall ( 9 bricks ) Efficiency evaluation for pi- inteaction Scan Back location Efficiency evaluation for brick to brick connection to down steam (3) Test for Brick to Brick Connection ( Masahiro Komatsu ) Scheme (a) Expose bricks to pi/mu/e to simulate tracks to be connected (b) Refreshed brick Try to connect to down brick Edge effect on connection to side brick Determine maximum cosmic ray exposure density to allow brick to brick connection Cosmic ray exposed for momentum measurement acts as background for connection Efficiency evaluation (4) Scan Back Location Scheme ---> will be merged into above 3 discussions Labels on emulsion sheets Do we need fiducial marks on each emulsion sheets ? How to set an emulsion sheet on a stage ? How to treat edge events ? Organizers are allocated as shown above and they should circulate detailed description and questions to be answered at the workshop soon.
| N. D'ambrosio ( Napoli ) |
| G. De Lellis ( Napoli ) |
| P. Strolin ( Napoli ) |
| P. Migliozzi ( Napoli ) |
| G. Wilquet ( Brussel ) |
| G. Rosa ( Roma ) |
| M.T. Muciaccia ( Bari ) |
| S. Simone ( Bari ) |
| M. Desario ( Bari ) |
| Y. Sato ( Utsunomiya ) |
| I. Tezuka ( Utsunomiya ) |
| C. Sirignano ( Salerno ) |
| E. Barbuto ( Salerno ) |
| J. Damet ( Bern ) |
| S. Gamper ( Bern ) |
| S. Gabriele ( Bologna ) |
| C. Michela ( Bologna ) |
| I. Laktineh ( Lyon ) |
| H. Shibuya ( Toho ) |
| S. Ogawa ( Toho ) |